  • V.2(46), 2021
    31-40

    Study of the influence of climatic factors for pin insulators with rfid indicators

    The work relates to the application of a new method of noncontact RFID monitoring of the condition of insulators for overhead power lines, including signaling, centralizing, blocking, and longitudinal power supply lines . A significant number of accidents occur due to the breakdown of insulators and imperfection of control methods. It is proposed to use a non-contact RFID control system for overhead power line insulators, which consists of a reader with a transceiver and an antenna, standard insulators with RFID indicators and special software. The aim of the research is the influence of climatic factors on the components and assembly structures of pin insulators with RFID indicators and the operation of the RFID control system in general. The selected study samples are a radio frequency tag, an aluminum-coated plastic cap with an integrated tag, and a pin-shaped porcelain insulator with an RFID indicator in the assembly. The climatic tests were carried out in the testing center of technical means of railway transport of the Ural State University of Railway Transport (IC TSZHT USUPS). Temperature changes were simulated from -60 to +50 ° С with air humidity up to 93%. The results on the adhesive properties and electrical conductivity of a conductive coating on a polyethylene surface and the stability of the functioning of RFID tags are presented and analyzed. Suggestions for improving the components and assembly design are given. Firstly, to use a screw thread on the top of the pin instead of a special knurling, which will reduce mechanical stress during installation of the structure of individual components and will reduce the error in the installation dimensions to improve the reception and transmission of signals between the reader and the tag. Secondly, sandblasting of the surface of the polyethylene cap can improve the adhesion of the surface to the conductive coating, which will increase the electrical conductivity of the structure. The result of this work proves that the developed RFID control system of insulators functions in the climatic conditions specified by GOST, which allows to recommend its implementation in the lines ts use in lines of devices with a voltage of 6-10 and 35 kV.
  • V.1(21), 2015
    54-59

    Investigation of electrostatic field on the insulator strings catenary

    The article describes themain types ofdamageinsulatorscontact network, presents statisticsfortheirfailures. Identified weaknessesin existing methodsof diagnosingsayabout the relevance ofthe problem, especially in the areasof railwaysDC. Made experimental investigationson the measurementof the electrostaticfield on theinsulator strings. Analysis of the studiesshowed that the presencein the string of faultyinsulatorsleadsto an increase inthe electrostatic fieldaround them. Proposed a technicaldevice noncontact measurementof electrostatic fieldandmethod of determining thefaultyinsulatorin the string.
  • V.1(37), 2019
    64-72

    Method of remote diagnostics suspended porcelaininsulator dc catenary

    A method for remote diagnosis of suspended porcelain insulators based on the pulse method is proposed. The form of test pulses for diagnosing isolators in the area of the DC contact network is determined. The main diagnostic parameters of the supplied and recorded pulses are given and calculated. The possibility of determining the distance to the faulty garland depending on the amplitude value of the diagnostic pulse has been revealed. The change of the peak value of the pulse decay depending on the resistance of the insulator string is considered. The proposed method allows localizing the position of a faulty insulator string at the DC power supply section, and subsequently reliably determining the faulty insulator in the festoon.
  • V.4(52), 2022
    89-96

    Control of the pressing forces of the pandrol fastclip fastening terminals on the sole of the rails

    This article discusses the problem of loss of elastic properties of Pandrol Fastclip rail fasteners during operation. The research is related to predicting the dynamics of changes in the elastic properties of the Pandrol Fastclip clamping terminals during their long-term operation and provides for the creation of control methods (regulation) by pressing the fastening terminals on the sole of the rails, which guarantees the safety of trains with set speeds. On the basis of the conducted research, the design of a device that increases the pressing force of the fastening terminals on the sole of the rails has been developed. This device will provide optimal parameters for attaching rails to the sub-rail base at all stages of railway track operation. At the same time, there will be no need to replace the expensive imported elastic terminals of the Pandrol Fastclip fastening in cases of a decrease in the elasticity of the terminals in the current path. The research results are relevant for dozens of foreign railways where modifications of the Pandrol Fastclip fastener are operated: Pandrol Fastclip FC, Pandrol Fastclip FCA, Pandrol Fastclip FE, Pandrol 350, Pandrol SFC, Pandrol 1520, etc. The proposed technology for carrying out work to improve the technical condition of the intermediate rail fastening structure will not require the provision of "windows" in train schedules, which will not affect the carrying capacity and capacity of the railway track and will not affect the delays of scheduled trains.
  • V.3(27), 2016
    91-99

    Modeling and experimental investigation of the distribution of the electrostatic field on a garland suspended porcelain insulators

    The article deals with the distribution of the electrostatic field around the garland of porcelain suspension insulators containing defects. Achieved the distribution simulation of the electrostatic field around insulators in the software package Elcut. We get a picture of field distribution around the insulators for the environment with different dielectric constants. A comparative analysis of simulation results and experimental studies on the basis of which revealed the possibility of diagnosing the parameters of insulators of the electrostatic field.
  • V.4(20), 2014
    92-97

    Comparative analysis of simulation results and experimental data device remote diagnostics insulator contact systems

    The article presents results ofmodeling andfull-scaletesting of the devicefor remotediagnosisinsulatorscatenaryrailway transport. The maincauses ofbreakdownof insulators. Presents statistics offailurecatenaryinsulators. The plotof the contactnetwork is presentedin the form ofthe line modelwith distributed parameters. To create a virtual model of the device and the line was selected program Multisim 12.0. Described bya block diagramof the devicefor remote monitoringcatenaryinsulators. Shows theprinciple of operationof the deviceto control thecatenaryinsulators. Present a schemeof the experimentat the siteof contact networkOSTUlandfill. Parameters are calculatedareaof contact network. Chosenform ofdiagnosingpulsesto determine thepossible location ofthe faultyinsulator.
  • V.4(20), 2014
    97-104

    Determination procedure of the condition of the insulators used in an overhead power transmission line of 6 - 10 kv

    In connection with the negative effects caused by the fault of the insulators used in an overhead power transmission line of 6 - 10 kV, it is suggested controlling a condition of a post insulator by the device that responses when breakdown current goes through an insulator. The work of the device for identification of insulators defects is described. Equivalent circuits of an alarm device connection with an insulator in an overhead power transmission line are given. The basic processes, that occur in a system of a supporting insulator of an overhead power transmission line in a serviceable condition and if there is a defect in view of geometric capacitance, absorption current, steady leakage current and surface current of breakdown, are considered.
  • V.1(29), 2017
    112-118

    Method of ensuring the withdrawal of widening of gauge at curves with radius less than 350 m

    In the article the issues on creation of branch of track width when changing it in the curved track with radius less than 350 m. Presented the existing methods of widening or narrowing the width of the track in the curves section of track. We propose a method of change of gauge in curved track is from 1520 to 1530 or 1535 mm. to the Proposed method of drainage of the track width is carried out by the existing structures of the elements of the superstructure. The proposed method of drainage of the track width gives a smooth fit of the rolling stock in curve track section and provides the requirements of the applicable standards.