Search results
-
V.1(37), 2019
112-121In the work completed a study of shape vertices a unimodel probability density function (kurtosis) on the output of the nonlinear converter «phase shift - code, which is the most important parameter for evaluating conditions of finding mode to this function. To increase the accuracy of assessment shifts phases when there is high level of random noise is defined not only quality, but also quantitative dependence of the kurtosis probability density function on the output of the nonlinear converter «phase shift - code» of Standard deviation phase fluctuations of the signal at its input. The mathematical model of the distribution function on the output of the converter «phase shift - code» for research and implementation of algorithms improve noise immunity measure phase shifts between harmonic components of voltage and current in traction power supply rail transport networks. -
V.2(30), 2017
113-123In work done modeling and analysis of noise immunity of the proposed measurement method of phase shifts between harmonic components of voltage and current in traction power supply rail transport networks and estimation of maximum permissible noise level, where workability digital devices used to study phase shifts in these conditions. The simulation results have shown that the probability density function on the output of the nonlinear converter «phase shift - code» remains a unimode at any ratio range converter and standard deviation of the phase of the input signal. Implementation of researched ways of microprocessor-based digital device guarantees the stability and accuracy of measurement results in traction phase shifting networks of power supply of railway transport in the presence of high levels of industrial noise, nonlinear fast variable nature of the traction load, sparking the pantographs for electric locomotives in contact network and use recovery systems based on pulse converters. -
V.4(36), 2018
132-141Developed Methodology let make the calculation of coaxial cable parameters with account of the frequency of the transmitted signal. The comparative analysis of parameters of RC 50-7-28 and RG142 cables has been made with the values have been got by the measuring with the circuit analyzer according to the reference book with the results of the calculations. Check the accuracy of the calculation has pointed out the necessity for account of complementary factors for the purpose of much more correct account cable attenuation in the frequency spectrum.