• Рус Русский
  • Eng English (UK)

Scientific and technical journal established by OSTU. Media registration number: ПИ № ФС77-75780 dated May 23, 2019. ISSN: 2220-4245. Subscription index in the online catalog «Subscription Press» (www.akc.ru): E28002. Subscription to the electronic version is available on the «Rucont» platform.
The journal is included in the Russian Science Citation Index and in the List of Russian Scientific Journals .

Search results

  • V.3(27), 2016
    38-44

    Features of compensating devices choice in traction power supply system with using optimally criterion

    Method of installation places and power choice of reactive power compensation devises in traction power supply system in condition of increase freight miles are introduced in this article. Approaches to definition of reactive power optimal criteria with reactive power compensation installation are denoted. Three criteria for estimation of reactive power compensation installation are offer to review. There is provided method of optimality assessment of this choice.
  • V.4(48), 2021
    39-46

    Methodology of selecting compensating devices in the ac traction power supply system

    The paper considers a traction power supply system with a voltage of 27,5 kV AC. In the MATLAB-Simulink software environment, a calculation model has been developed that takes into account the parameters of the external power supply system, the train schedule and the current consumption of the electric traction load in the inter-substation zone. It is shown that when choosing the power of the compensating device according to the average value of the reactive power consumed by one train, its passage through the inter-substation zone with direct current causes the same average power losses in the wires of the catenary as in the absence of a compensating device. An increase in the number of trains simultaneously located in the inter-substation zone with the same power of the compensating device entails a decrease in power losses in the wires of the catenary relative to a similar situation without a compensating device, however, the reactive power is only partially compensated. In the calculations of compensating devices, it is proposed to take into account the real existing train schedule, based on the probabilistic assessment of which the average daily reactive power consumed by the electric rolling stock is determined. In this case, it is necessary to take into account the power losses in the catenary. The use of unregulated compensating devices is advisable in areas with a constantly present load. When choosing step devices for transverse capacitive compensation, it is proposed to calculate their power based on a probabilistic analysis of the train traffic schedule and current consumption in the inter-substation zone. When the probability of the appearance of a certain number of trains exceeding 50%, the most effective are compensating devices, the power of which is selected on the basis of the average power consumption of all trains without taking into account the time of no load in the inter-substation zone, as well as two-stage devices, the power of the first stage of which is selected according to the current consumption of the two most likely occurrences of the number of trains.
  • V.1(37), 2019
    54-63

    Analysis of power losses in the main equipment static varcompensators taking into account the non-sinusoidalvoltages and ways of its reduction

    With the purpose of providing capacity on the West-Siberian railway, in recent times, adjustable reactive power compensation devices have been introduced. The schematic construction and parameters of such devices on the market are significantly different. In connection with this, it is necessary to choose from the set of schemes the most effective, corresponding to specific technical and economic conditions. The article assesses the power losses in the main equipment of two devices from different manufacturers, namely static thyristor compensators of reactive power produced by "KER Holding" Kazan and "Aidis groups" Moscow, installed on the Alambay and Novaya Dubrava sectional posts of the West Siberian Iron roads. The power losses in the equipment are calculated taking into account additional losses from the influence of higher harmonic components. The analysis of the circuit design of both devices in terms of loss reduction is carried out. Dependences of power losses in their elements on the generated reactive power and the current of the thyristor-reactor group are constructed. Probabilistic functions of the distribution of the current of the titrator-reactor groups of devices are given at preset settings. The results of measurements of power consumption of devices for own needs are presented. The effect of reducing power losses in the traction network from switching devices with losses in their main equipment is compared. On the basis of the work done, the elements with the greatest losses are identified. The features of each device, affecting the power loss in the main equipment, are described. Conclusions are drawn about the effectiveness of the schemes under consideration. Methods for reducing power losses in basic equipment and consumption for energy consumption are proposed.
  • V.4(36), 2018
    106-112

    Strengthening the traction power supply systemof accurrent by the application of compensating devicesin the conditions of increased mass train handling

    The paper discusses the main limiting factors limiting the volume of transportation of high-volume freight trains. Designated approaches to solving the problems presented by the use of compensating devices. The paper presents the method of selecting installation sites and the power of compensating devices in the traction network, taking into account the growth in traffic volumes, allowing to evaluate the positive effect of the installation of compensating devices on the prospect of increasing traffic volumes. Determination of perspective power consumption is proposed to carry out using power consumption forecasting. To assess the effect of the installation of compensating devices in the traction network, three criteria have been proposed: unloading traction transformers, increasing the voltage level at the consumer, and unloading the power transmission lines.