  • V.3(43), 2020
    2-11

    Increasing the power factor of electric locomotives by upgrading the rectifier-inverter converters arms

    The subject of the research is the power thyristor converter of AC electric locomotives and its influence on the power factor of the locomotive. A new method for increasing the power factor of AC electric locomotives with thyristors power converters is proposed and analyzed. These electric locomotives include locomotives of the 2ES5K, VL85, EP1 series, etc. At the initial of the paper, the existing methods of increasing the power factor are briefly considered and their disadvantage in comparison with the proposed method is indicated. The drawback of existing converters is also analyzed, which consists in the presence of a thyristor opening delay at the beginning of the supply voltage half-cycle. The proposed method implies the modernization of the control circuits of the thyristors of the converter, due to which, at the beginning of the half-period, a control current is spontaneously created on the control electrode by means of the supply voltage. As a result, the thyristors open with a minimum delay after the start of the half-cycle. To verification the effectiveness of the proposed solutions, a computer simulation of the operation of the power circuit of an electric locomotive in the ORCAD program was carried out. Simulation was carried out for two options: a power circuit with standard converters and a power circuit with converters upgraded in accordance with the proposed method. During the simulation, the change in the value of the power factor of an electric locomotive was investigated at different currents of traction motors, zone and angle of regulation. Analysis of the oscillograms of converter various arms currents the revealed that when using the modernized converters, the moment of the end of the network switching occurs earlier than in the standard circuit. There is also no area with negative voltage at the output of the converter at the beginning of the half-cycle. At the end of the paper, the values of the electric locomotive power factor are given under various conditions. These results show that the use of the proposed method increases the power factor of an electric locomotive by an average of 1.2 percentage points.
  • V.1(41), 2020
    11-20

    Justification for the introduction of the sequential type twelve-pulse rectifiers in the underground power supply system

    The use of twelve-pulse rectifiers instead of six-pulse rectifiers leads to increased efficiency and efficiency of traction substations of the underground. On the basis of experimental research and analysis of circuit solutions, the conclusion is made about the advantage of a twelve-pulse rectifier circuit of a serial type over parallel-type circuits. The use of rectifiers with a parallel type circuit is possible only if there is an equalization reactor, without which technical and economic indicators are reduced. The introduction of the most rational twelve-pulse bridge rectifier schemes of the sequential type can be carried out by upgrading the installed equipment, or by industrial development by manufacturers of dry transformers with different typical power and rectifiers with tablet avalanche valves with coolers based on heat pipes.
  • V.1(37), 2019
    35-44

    Development of evaluation method of formation short circuit in the power circuits of the inverter of electric locomotive

    The article presents a method for determining the thyristor shoulders of the rectifier-inverter converter (inverter) of an electric locomotive, on which the control pulses are passed. The method is based on the analysis of the duration of the current switching of the thyristors of the inverter shoulders and the rate of rise of the rectified current in the inverter circuit of the electric locomotive. The implementation of the method is carried out by refining the software of the microprocessor control system of the electric locomotive. The simulation of electromagnetic processes of rectifier inverter Converter of AC locomotive series 3es5k "Ermak" in the mode of regenerative braking during emergency operation is carried out on the example of missing control pulses on thyristor shoulders VS2 and VS7. As a result of modeling, data are obtained that confirm the effectiveness of the method proposed by the authors
  • V.3(19), 2014
    50-54

    Alteration the algorithm of the rectifier-inverter converter for electric locomotive vl85 at the higher areas of regulation

    In the article suggests a changing the algorithm of the rectifier-inverter converter electric locomotive VL85. This will allow the individuallyto regulatevoltageon traction engines. In this case willpreserve a singlecentralized system ofcontrol of allelectricconverters. The proposed solutions may be used for liquidation started spinning of wheel locomotive. Tractive force the remaining wheelsets will not decrease.
  • V.3(39), 2019
    57-67

    Assessment of the moscow central ring energy efficiency potential through the use of rectifier-inverter converters

    This article presents the results of changes calculations in the energy efficiency indicators of the Moscow Central Ring, such as the specific consumption of electricity released for traction by trains of traction substation meters, specific recovery, technical losses of electricity in the traction power supply system when it is transferred to electric rolling stock, including technical recuperation energy loss, depending on various installation options of rectifier-inverter converters in traction substations part.
  • V.1(45), 2021
    66-75

    Rectifier-inverter converter of an electric locomotive based on igbt transistors as a way to increase the capacity of railway sections

    The purpose of this article is to analyze the voltage drop in the contact network caused by poor-quality operation of an alternating current electric locomotive when passing heavy trains. Heavy-haul traffic is considered today as a valid and necessary tool for increasing weight norms and increasing the throughput of railway sections. The article provides statistics on the passage of heavy and connected trains on the Krasnoyarsk railway for 2019 and 2020. For the effective use of heavy traffic, it is necessary to solve a number of problems, one of which is to reduce the voltage in the overhead network when passing heavy trains, this negatively affects the speed of the train along the haul, the conditions for cooling the power equipment of the electric locomotive deteriorate, etc. As a result of the analysis of the operation of the thyristor rectifier-inverter converter, a number of disadvantages were revealed. The reason for the low power factor of the electric locomotive lies in the use of an outdated element base based on thyristors, their closure is carried out only in the next voltage half-cycle, long-term switching and a large opening angle of thyristors leads to a significant reactive current in the contact network. Based on the analysis the voltage losses at the current collector, it was concluded that it is necessary to reduce the duration of the switching process of the arms of the rectifier-inverter converter, in which a short circuit occurs in the secondary winding of the traction transformer. An alternative version of the converter based on fully controlled semiconductor devices - IGBT transistors is proposed. The ability to open and close at any time of such elements allows you to minimize the phase angle and increase the power factor. Due to the almost instantaneous switching of transistors, the distortion in the contact network is minimized.
  • V.2(50), 2022
    74-85

    Influence of the power bus design on the current symmetry in the arm branches of a rectifier-inverter converter on igbt-transistors in their parallel connection

    An urgent issue is to increase the power factor of electric rolling stock. One of the ways to increase the power factor in the traction and regenerative braking modes was proposed by the scientists of IrGUPS - this is the use of a rectifier-inverter converter on IGBT with modified control algorithms. This solution allows to significantly reduce the consumption of reactive current from the contact network, increase the capacity of railway sections, increase the technical speed, increase the efficiency of the traction power supply system, and also increase the amount of electricity returned to the contact network in the regenerative braking mode. The study of the performance of this converter is of interest. The transported volumes of goods on the railway lines of the Russian Federation continue to increase. One of the key links in ensuring the specified growth rates of tonne-kilometer work is the availability of powerful traction rolling stock equipped with an appropriate traction drive. A powerful traction drive is characterized by the consumption of significant current. To ensure its flow over the arms of the converter, a parallel connection of power semiconductor devices is used. For modern converters of electric locomotives, 4 parallel branches of power switches are used in the arm. The features of the parallel operation of the arm branches affect the performance of the converter on IGBT transistors. This article proposes to consider one of these features, namely the influence of parasitic inductances on the distribution of currents in the parallel branches of the converter, depending on the connection point of the AC power bus. The study was carried out using the Matlab Simulink software package. The article discusses various options for the topology of connecting power buses and presents diagrams of the distribution of currents in the parallel branches of the arm for each connection method. An assessment was made of such parameters as the spread of the peak current of switching on the branches of the arm, the time of current equalization during the conduction period, and the difference in the magnitude of the current in specific branches. Based on the results of the study, as well as taking into account the existing dimensions for the equipment of AC electric locomotives, a conclusion was made about the most optimal option for connecting power buses.
  • V.3(23), 2015
    79-85

    The diaognostics of traction substations power rectifiers converters

    Various converters are operated at electric railways traction substations whose rectifiers design includes plug-in power rectifiers and pill ones. Such a variety of rectifiers design causes the problem of the power supply reliable operation unavailability both of volumes and of quality information concerning the characteristics and diagnostic parameters of power semiconductors rectifiers. For a possible prediction of the diodes and thyristors proper operation, new instruments as well as simple technologies of the preventive diagnostics, correspondent to the state and industry standards and instructions should be developed. One of the most accurate methods to determine not only the serviceability of rectifiers but also to forecast their wear - life, is the diagnostic method of recurrent peak backward current. This method is the basis for the design of a peak backward current meter which is used on the Western-Siberian railway. Using this device the screening of about thirty thousand rectifiers was carried out which resulted in the sorting of out-of-work rectifiers, predicting long term rectifiers conditions. The statistical analysis of the research allowed to determine the number of measures to improve the reliability of traction substations converters.
  • V.3(19), 2014
    81-87

    Usage of 1-phase transformer with additional tap at medium point of secondary winding simulator for system of traction motor excitation current stabilization investigation

    Single-phase transformer with an additional tap at the middle point of the secondary winding is a very common element in the various electrical circuits, including on-board electric rolling stock. A typical case is powered from the transformer zero full-wave rectification circuit. The aim of the article is to provide a detailed description of the computer model developed by the author of said transformer, built on the basis of a combination of circuit and operational design principles. The proposed model can also be used to describe the process in a single-phase two-winding transformer without additional tap, given the possible connection group I / I-6 or I / I-0. Connection groups can be considered individually for each half of the secondary winding in case of using of additional tap. Shows an example of embedding the transformer model in a more complex computer model of the electric traction DC motors excitation current stabilization system, which includes a computer model of a saturable reactor, thyristor rectifier, system of pulse-phase rectifier control and control loop with a proportional-integral current regulator and boost nonlinearity. Obtained during the simulation graphics excitation current in the field winding of collector traction motor and its reactive component show that the above system of stabilization of the current and its computer model of functional and successfully fulfill their functions: at the downturn of the armature current excitation current is maintained by the growth of the current make-up of excitation control rectifier. The correct operation and ease of use of the developed computer model of a single-phase transformer with an additional tap at the middle point of the secondary winding is stated.
  • V.3(51), 2022
    112-125

    Assessment of voltage losses in the ac traction network for two different types of the locomotive’s rectifier-inverter converters: on thyristors or igbt-transistors

    The paper deals with benefits of a new rectifier-inverter converter of an electric locomotive based on IGBT-transistors. Main directions of heavy haul traffic's development are considered for Siberia and Russian Far East electrified railways. Throughput and carrying capacity of power supply devices extremely depends on the voltage level in the catenary network of electrified sections of railways. Objects of our research are electric parameters of the 25 kV, 50 Hz AC traction power supply system. Operation parameters of two different types of the electric locomotive’s rectifier-inverter converters are calculated and discussed. We investigated operation parameters for thyristor-based and IGBT-transistors- based rectifier-inverter converter. Current and voltage curves for the thyristor and the transistor type of the rectifier-inverter converter are given and discussed. Similarity factor of current curves for electric locomotives was calculated by equivalent sinusoid’s .method. Quantitative assessment of the voltage level, currents and voltage losses in the AC catenary network is given. The graph-analytical method was used for constructing currents and voltages vector diagrams. It is proved that electric locomotives with a new rectifier-inverter conversion based on IGBT transistors provides a reducing of the total voltage losses in three times in the traction network comparing the thyristor conversion's operation.
  • V.3(31), 2017
    114-123

    Indicators improvement of the traction substations multiple pulsed rectifiers energy efficiency

    The article deals with the introduction of a twenty - four pulse rectifiers with various rectification circuits on direct current traction substations. The results of the operation of a twenty-four-pulse rectifier installed at one of the traction substations prove the expediency of using such a converter. The variants of the existing equipment modernization, which is a part of the six- and twelve-pulse rectifiers in order to use it in the creation of twenty-four-pulse rectifiers, as well as the requirements for the creation of such rectifiers in industrial design are given.
  • V.4(28), 2016
    124-134

    Algorithms and structural solutions for construction the system of monitoring and electricity metering on the feeders of the contact network

    We propose the concept of the new system for monitoring and electricity metering on the feeders of the D.C. contact network. The system is based on previously designed prototype that has been put into operation, and differs from it in new solutions that allow to achieve greater mobility and simple scalability. We describe the basic technical solutions, the system functions as well as its potential.