Search results
-
V.3(43), 2020
66-75The article presents the main results of experimental studies within the boundaries of the Fadino - Novoseletsk, Novoseletsk - Strela interstitial zones of the Entrance - Irtysh section. As a result of the research identified problems that currently hinder the online monitoring of operational parameters of the electric rolling stock (EPS) and power supply devices: a lack of data on the work of the traction substations, the presence of EPS without registration motion parameters (RAPS), the lack of process data collection with RAP, the lack of a single source and process for obtaining data, insufficient memory storage device of cartridge, lack of data latch on the locomotive in General, lack a set of fixed parameters, non-constant sampling of parameter fixing, insufficiently detailed final documentation, imperfect software for exporting data from cartridges and lack of binding to global time. Shown the possibility of joining data from different automated systems of JSC "RZD" and measuring systems OSTU, which will allow us to estimate the losses in the traction network, the expense on own needs of electric rolling stock , the electric power consumption for traction and return of electric energy to contact network, as well as move forward with implementation of predictive control operation modes of the electric rolling stock and power infrastructure and Railways in a changing environment in the transportation process, to ensure the best conditions for the realization of tractive effort, regenerative braking, set train schedules, including in case of critical restrictions on the part of the power supply system, preventing train traffic from stopping. -
V.1(37), 2019
81-91The article considers an approach that allows to reduce the asymmetry of consumed currents by traction substations of railways from a three-phase power supply system using a compensating device with an asymmetric structure installed at the substation. Reactive currents of the compensating device allow to redistribute between phases of the traction transformer active and reactive power of asymmetric traction load and to receive symmetric load of three-phase power supply system. The theorem is proposed to determine the conductivities and reactive currents of the branches of a compensating device with an asymmetric structure depending on the traction loads. The article presents the calculated expressions, which can be used to calculate the conductivity and reactive currents of the branches of the compensating device for any traction load of the feeders, in which the equivalent load, including the reactive currents of the branches of the device and the currents of the feeder zones will be symmetrical and active. As an example of the application of the theorem and the proposed expressions, a test problem is presented in which the secondary winding of a traction transformer with asymmetric traction load of feeders is considered, the conductivity of the branches of the device is calculated. With the use of vector diagrams shows the receipt of a symmetrical system of currents of the secondary winding of the traction transformer. Mathematical expressions allowing to realize the necessary law of regulation of reactive currents of the device are given. The necessary ranges control of reactive currents of the compensating device on traction substation on the set probabilistic laws of change of traction loadings are defined. Various options for the practical implementation of a compensating device that will provide the necessary inductive or capacitive current of each branch are considered.