V.2(26), 2016
78-91The paper is devoted to the calculation of the electrical quantities distribution in the system of three conductors. The first conductor is located on the surface of a uniform soil and the other two conductors are located at depths of h and h . As result, analytic expressions of current, potential and leakage current density in the first underground construction with considering the influence of the second construction was obtained. The influence of second construction increases the value of electrical quantities in the underground construction. The analytic expressions were obtained using Fourier transform method. The analysis showed the influence of the leakage current and insulation resistance of the second construction on the electric quantities distribution in the first construction