V.2(30), 2017
2-8Abstact. During automated rheostat tests of locomotives itʹs necessary to control a lot of parameters of the diesel generator set and support systems. Due to the features of perception of the information by human the control is brought to the observation of a small number of parameters. Implementation in practice of rheostat tests of automated systems of inspection and testing allowed to expand the amount of received information. In this article is offered using automated control systems of diesel-generator sets parameters during rheostat tests which allow to accumulate and analyze test date using developed protocols forms and pivot tables with parameters in entire range of loads, also it helps to determine the quantitative index of a technical condition of diesel-generator set. -
V.4(52), 2022
22-31One of the properties of the reliability of the power supply of electric rolling stock of railways is the trouble-free operation of the traction power supply system in various modes of its operation. For post-emergency and forced modes of operation of the traction power supply system, a decrease in load capacity is characteristic. In order to ensure the throughput and carrying capacity of the railway section by traction power supply devices, it is proposed to consider the use of electric power storage devices on electric rolling stock and in the traction power supply system. Studies conducted by domestic and foreign researchers allow us to evaluate the effectiveness of alternative solutions to improve the reliability of power supply, which include various options for the use of electric power storage devices on electric rolling stock and in the traction power supply system. This article presents the results of a review of these solutions, a simulation model of a traction power supply system and an electric rolling stock with power storage devices based on various batteries and a supercapacitor is proposed. Modeling of changes in the modes of operation of the traction power supply system is carried out taking into account the state control of switching devices. The calculation results allow us to estimate the voltage drop at the output of electric power storage devices, including taking into account the exponential zone of the discharge characteristics of batteries, to estimate the voltage change for a given electric traction load depending on the energy intensity of the storage device, made on the basis of the most common types of batteries and a supercapacitor. -
V.3(23), 2015
68-72Rheostat trials must be carried out after repairing of a diesel locomotive. As a rheostat it is used a complex of equipment and it is taken a separate building for the staff, which must be situated at a set distance from office buildings. In order to keep the building for the staff warm central heating is used. The net cost is extremely high and transit heat losses are often comparable with effective consumption of the heated building. In this work the possibility to utilize the secondary energy resources for heating the stations is considered where rheostat trials are supposed to be carried out. It is noticed in separate depots that the measures of heat energy utilization from load rheostats have already been applied, but they are not widespread. There are external restrictive factors which limit the adoption of heat-recovery installations and also technical and organizational factors as well. There have been proposed principal measures which could be considered in case of the adoption of heat-recovery installations. Calculations are performed by heat energy generation by a rheostat during typical trials of diesel locomotives TEM2 and heat quantity of heat-transfer agent in typical load water rheostats. It is proposed that the plan to utilize secondary energy resources in low temperature heating systems will be effective. It is also mentioned the utilization of low temperature heating systems has many advantages. The required heat energy generation of heat-recovery installation for each month of the year have been calculated, and Station Omsk depot is one of the example where these calculations have been performed. It is noted required quantity of trials for heat loss compensation coincide with station operating schedule of rheostat trials in the majority of depots and would like to apply the indicated trial method. The calculated economical cost of these measures along with capital costs for the speed of completing the building should be considered when calculating the total cost of the station over the open rheostat tank. -
V.4(40), 2019
70-77The article deals with the possibility of energy utilization of exhaust gases of diesel-generator sets of locomotives during load tests. The calculation of the amount of heat carried out during tests with exhaust gases. Possible variants of heat utilization with the use of various heat exchangers are considered. -
V.1(33), 2018
109-117The article deals with the analysis of the modes of operation of shunting locomotives; characteristics of the setting characteristics of the traction generators when performing resistance tests of locomotives. The statistical average values of the load parameters of diesel generator sets of shunting locomotives TЭM2 in the process of performing shunting work on marshalling and precinct stations. When monitoring the external characteristics of the locomotive when performing resistance tests with the ASKI "CYPRESS" was observed of the external characteristics of a normal ("classical") and "convex" shape. Normal (classical) external characteristics of the locomotive TЭM2 No. 1 equidistant removed from the borders of the tolerance field; and "convex" external characteristics of the locomotive TЭM2 No. 2 , in the field of tolerance, support of the constancy of the power diesel generator sets, due to the imperfection of the machinery of the regulatory system, particularly the Electromechanical characteristics of the pathogen.