• Рус Русский
  • Eng English (UK)

Scientific and technical journal established by OSTU. Media registration number: ПИ № ФС77-75780 dated May 23, 2019. ISSN: 2220-4245. Subscription index in the online catalog «Subscription Press» (www.akc.ru): E28002. Subscription to the electronic version is available on the «Rucont» platform.
The journal is included in the Russian Science Citation Index and in the List of Russian Scientific Journals .

Search results

  • V.3(15), 2013
    17-24

    Calculation of contact pressing of a current collector the «aist» taking into account change of aerodynamic carrying power at various climatic conditions and working height

    In article it is made a calculation contact pressing taking into account change of aerodynamic carrying power depending on climatic conditions (in one and a two-phase stream), and as at change of working height of a current collector. Comparison of the received results with experimental data is executed.
  • V.2(50), 2022
    30-44

    Calculation of parameters and evaluation of the possibility of using chain compensated contact suspension with lever for a three-phase traction power supply system

    A variant of application of a contact compensated chain suspension with levers and lateral current collection for a three-phase traction power supply system (TSTE) is considered. Two different-phase contact suspensions are located on different sides of the track axis. The electric rolling stock must have two current collectors that press on the contact wire from the track axis in opposite directions. The description of the design of the contact suspension as a whole and the main components, in particular, the fastening of the rods, which makes it possible to provide a vertical zigzag and limit the transverse movement of the contact wire, is made. At points at the supports, the levers are connected to the consoles and have a knot to create angular rigidity. In addition, the rotation of these levers is limited towards the axis of the path and in the opposite direction. This prevents the possibility of lashing of different-phase contact wires. In accordance with this design, a mathematical model of this contact suspension was developed based on the finite element method, which provides calculation in statics and dynamics, taking into account the current collector. To describe the pantograph, a common three-mass model is used. Based on the analysis of the results obtained using this model, the influence of the design parameters of the suspension, cross wind and the speed of the pantograph movement on the quality of the current collection is determined, the limits of applicability of the suspension under consideration, depending on the value of these parameters, are established. It has been determined that, in contrast to a conventional contact suspension with a vertical current collection, for suspensions with a lateral current collection, a side wind has a significant effect on the quality of the current collection. It is the wind speed that is the main factor limiting the possibility of using a suspension with lateral current collection.
  • V.1(13), 2013
    54-63

    Parametric identification of the transformer power traction substation

    The new method of parametrical identification of three winding transformer by using phase domain is proposed. Transformer model represents as lattice equivalent circuit.
  • V.4(16), 2013
    69-77

    Analysis of the causes of errors of measurement

    Analysis of the causes of errors of measurement of phase shifts of harmonic components in electrical railway traction networks and describes how to improve the accuracy of measurement.
  • V.1(13), 2013
    76-82

    Adaptive method for finding symmetrical components in three-phase electric supply systems

    Under consideration the method to determine the positive and negative sequences of fundamental voltage and current harmonic in the three-phase power supply systems, based on the Clark transformation and adaptive filtering.
  • V.3(19), 2014
    81-87

    Usage of 1-phase transformer with additional tap at medium point of secondary winding simulator for system of traction motor excitation current stabilization investigation

    Single-phase transformer with an additional tap at the middle point of the secondary winding is a very common element in the various electrical circuits, including on-board electric rolling stock. A typical case is powered from the transformer zero full-wave rectification circuit. The aim of the article is to provide a detailed description of the computer model developed by the author of said transformer, built on the basis of a combination of circuit and operational design principles. The proposed model can also be used to describe the process in a single-phase two-winding transformer without additional tap, given the possible connection group I / I-6 or I / I-0. Connection groups can be considered individually for each half of the secondary winding in case of using of additional tap. Shows an example of embedding the transformer model in a more complex computer model of the electric traction DC motors excitation current stabilization system, which includes a computer model of a saturable reactor, thyristor rectifier, system of pulse-phase rectifier control and control loop with a proportional-integral current regulator and boost nonlinearity. Obtained during the simulation graphics excitation current in the field winding of collector traction motor and its reactive component show that the above system of stabilization of the current and its computer model of functional and successfully fulfill their functions: at the downturn of the armature current excitation current is maintained by the growth of the current make-up of excitation control rectifier. The correct operation and ease of use of the developed computer model of a single-phase transformer with an additional tap at the middle point of the secondary winding is stated.
  • V.1(49), 2022
    83-94

    Modeling of electromagnetic fields of a three-phase traction network

    The aim of the research presented in the article was to develop computer models for determining the electromagnetic fields (EMF) generated by three-phase 25 kV traction power supply systems (TPSS). In contrast to traditional single-phase TPSS, three-phase systems are electromagnetically balanced, provide symmetric loads of substations, increase voltages at current collectors of rolling stock, reduce asymmetry and non-sinusoidality in 110 - 220 kV supply networks. However, the issues of quantitative assessment of electromagnetic safety conditions in three-phase traction networks remain unstudied. To implement the formulated goal, we used the methods of modes and EMF simulation developed at the Irkutsk State University of Railway Transport, the distinctive feature of which is the use of phase coordinates; in this case, the models of TPSS elements are formed on the basis of lacelike equivalent networks. The simulation was carried out for three-phase TPSS schemes of different complexity, in which case the complex traction network was implemented by modifying the model of a real TPSS of one of the main railroads of Eastern Siberia. Simulation results indicated that compared to the typical TPSS 25 kV, the maximum electric field strength increases by 2.5 % in the three-phase system. The maximum value of the magnetic field strength decreases by 26 %. Similar indicators for average values are 2.6 and 19 %. The proposed methodology and the developed computer models can be used in the design of promising three-phase TPSS. In the conditions of power engineering digitization, the application of this technique in practice will allow to apply a scientifically validated approach to the analysis of electromagnetic safety conditions traction networks and to develop its improvement.
  • V.2(30), 2017
    99-112

    Analysis of the reception of signals of the satellite radionavigation system by phaseed antenna grids in a complex of safety devices for locomotive

    The structure of a complex of locomotive safety devices (CLSD) is analyzed. A comparison of technical characteristics and design features of ground stationary and transport antennas of the receiving equipment of the global satellite radio navigation system (SRNS) is made. On this basis, the importance of using SRNS in the CLSD structure is shown. It has also been shown that the decrease in locomotive positioning errors associated with the need to increase the signal-to-noise ratio at the input of the receiver can be achieved by the use of active phased array antennas (APARs). APAR are able to form narrowly directional patterns with the commutation of their maximum directions in accordance with the coordinates of the constellation's navigation satellites. Features of the formation of narrowly directional patterns and the possibility of controlling them in a linear and flat uniform APAR are considered. It is shown that the use of APAR in the ground-based equipment of the user is associated with the need: a) changing the approach to designing it for specific applications, - a flat surface of the required size should be provided in the design; b) the modernization of the algorithm for receiving and processing SRNS signals, which must take into account the finite switching time of the radiation patterns, the angle of the mask, the number and coordinate distribution of the navigation satellites in the working constellation.
  • V.4(28), 2016
    101-108

    Determination of parameters of compensating devices with asymmetric structure for reduction of voltage unbalance and reactive power compensation in the low-voltage three-phase electrical network

    The article considers one of the ways of improving the energy efficiency of three-phase power supply system of industrial and railway enterprises. Presented and proved a theorem, which allows to determine the necessary conductivity and the reactive branch currents compensating device with asymmetric structure, for which the equivalent conductivity of these elements and the load will be symmetrical and active. In three-phase electric circuit of an alternating sinusoidal current reactive elements allow to redistribute active and reactive power between the phases. The use of a compensating device with asymmetric structure will reduce losses from the occurrence of reactive currents, reverse currents and zero sequence in low-voltage three-phase power system. As an example of the use of the theorem and the calculated expressions for determination of conductance of the branches of the asymmetric compensating devices a special test problem was considered. It shows the values of power losses, the coefficients of voltage unbalance with and without using the device. Considered possible options for the practical implementation of such technical devices.
  • V.4(20), 2014
    105-111

    Application of the noise-protection method of measurement of phase displacement in the tractive networks of the power supply of rail transport

    Is executed the analysis of the permissible range of the fluctuation of the phase of signal on the entrance of digital measuring device with a study of phase relationships in the tractive networks of the power supply of rail transport, characterized by high noise level.
  • V.1(37), 2019
    112-121

    Improvement of noise immunity of digital phase-measuringdevices for the study of electrodynamic processesin traction substations of railway transport

    In the work completed a study of shape vertices a unimodel probability density function (kurtosis) on the output of the nonlinear converter «phase shift - code, which is the most important parameter for evaluating conditions of finding mode to this function. To increase the accuracy of assessment shifts phases when there is high level of random noise is defined not only quality, but also quantitative dependence of the kurtosis probability density function on the output of the nonlinear converter «phase shift - code» of Standard deviation phase fluctuations of the signal at its input. The mathematical model of the distribution function on the output of the converter «phase shift - code» for research and implementation of algorithms improve noise immunity measure phase shifts between harmonic components of voltage and current in traction power supply rail transport networks.
  • V.2(30), 2017
    113-123

    Evaluation of noise immunity measurement devices in the study of phase correlations in traction networks ac railway transport

    In work done modeling and analysis of noise immunity of the proposed measurement method of phase shifts between harmonic components of voltage and current in traction power supply rail transport networks and estimation of maximum permissible noise level, where workability digital devices used to study phase shifts in these conditions. The simulation results have shown that the probability density function on the output of the nonlinear converter «phase shift - code» remains a unimode at any ratio range converter and standard deviation of the phase of the input signal. Implementation of researched ways of microprocessor-based digital device guarantees the stability and accuracy of measurement results in traction phase shifting networks of power supply of railway transport in the presence of high levels of industrial noise, nonlinear fast variable nature of the traction load, sparking the pantographs for electric locomotives in contact network and use recovery systems based on pulse converters.
  • V.2(38), 2019
    117-127

    Simulation modelling the functioning the technological processes of rolling stock units repair

    The article discusses issues of simulation modeling of technological processes of repair of rolling stock components. A model of the technological process of repairing a trolley (mod. 18-100) of a gondola car in an ARENA environment is given.