  • V.4(32), 2017
    35-44

    Losses power in knots and units as the indicatorof efficiency of use the locomotive

    In article examines the indicator of the energy efficiency of the locomotive as an indicator of the quality repair and use the power (energy efficiency) of the locomotive. This indicator is calculated for electric locomotives that have undergone current repair of MW-3 or repair of a similar volume, based on the predicted additional power losses in the limiting units and units of the locomotive, determined taking into account their technical parameters and characteristics obtained as a result of the repair. The application of the proposed indicator as an indicator the efficiency the use of electric locomotives will allow to influence the improvement of their technical condition through the management the quality of repairs and the use of power.
  • V.1(37), 2019
    54-63

    Analysis of power losses in the main equipment static varcompensators taking into account the non-sinusoidalvoltages and ways of its reduction

    With the purpose of providing capacity on the West-Siberian railway, in recent times, adjustable reactive power compensation devices have been introduced. The schematic construction and parameters of such devices on the market are significantly different. In connection with this, it is necessary to choose from the set of schemes the most effective, corresponding to specific technical and economic conditions. The article assesses the power losses in the main equipment of two devices from different manufacturers, namely static thyristor compensators of reactive power produced by "KER Holding" Kazan and "Aidis groups" Moscow, installed on the Alambay and Novaya Dubrava sectional posts of the West Siberian Iron roads. The power losses in the equipment are calculated taking into account additional losses from the influence of higher harmonic components. The analysis of the circuit design of both devices in terms of loss reduction is carried out. Dependences of power losses in their elements on the generated reactive power and the current of the thyristor-reactor group are constructed. Probabilistic functions of the distribution of the current of the titrator-reactor groups of devices are given at preset settings. The results of measurements of power consumption of devices for own needs are presented. The effect of reducing power losses in the traction network from switching devices with losses in their main equipment is compared. On the basis of the work done, the elements with the greatest losses are identified. The features of each device, affecting the power loss in the main equipment, are described. Conclusions are drawn about the effectiveness of the schemes under consideration. Methods for reducing power losses in basic equipment and consumption for energy consumption are proposed.
  • V.4(16), 2013
    58-62

    Formation of the accounting periods for simulation modeling of the system of traction probabilistic method

    The article deals with the question of methodology stop imitation modeling when using modern instruments of mental resources, which are, for example, was Wednesday MatLab. In particular, analysis of factors that determine the duration of the simulation for a given level of accuracy desired results.
  • V.3(43), 2020
    66-75

    Monitoring of performance indicators of electric rolling stock and power supply devices using big data processing technologies

    The article presents the main results of experimental studies within the boundaries of the Fadino - Novoseletsk, Novoseletsk - Strela interstitial zones of the Entrance - Irtysh section. As a result of the research identified problems that currently hinder the online monitoring of operational parameters of the electric rolling stock (EPS) and power supply devices: a lack of data on the work of the traction substations, the presence of EPS without registration motion parameters (RAPS), the lack of process data collection with RAP, the lack of a single source and process for obtaining data, insufficient memory storage device of cartridge, lack of data latch on the locomotive in General, lack a set of fixed parameters, non-constant sampling of parameter fixing, insufficiently detailed final documentation, imperfect software for exporting data from cartridges and lack of binding to global time. Shown the possibility of joining data from different automated systems of JSC "RZD" and measuring systems OSTU, which will allow us to estimate the losses in the traction network, the expense on own needs of electric rolling stock , the electric power consumption for traction and return of electric energy to contact network, as well as move forward with implementation of predictive control operation modes of the electric rolling stock and power infrastructure and Railways in a changing environment in the transportation process, to ensure the best conditions for the realization of tractive effort, regenerative braking, set train schedules, including in case of critical restrictions on the part of the power supply system, preventing train traffic from stopping.
  • V.1(21), 2015
    69-74

    Controlling the irrational electricity consumption for train traction by the use of information-measuring systems of electricity metering on the rolling stock

    The article describes the types of irrational electric power losses for train traction and sets the annual planning levels of their improvement. Represented the basic methods of irrational electric power losses determination which are currently used in JSC "Russian Railways". Shown an example of the irrational losses determining algorithm in case of making up for train delay and given its description. Formulated technical results of the proposed method for determining the irrational electric power losses .
  • V.1(37), 2019
    81-91

    Definition ranges of current regulation compensating deviceto reduce the unbalance of the traction loads andimprove the power factor of the traction substationalternating current railways

    The article considers an approach that allows to reduce the asymmetry of consumed currents by traction substations of railways from a three-phase power supply system using a compensating device with an asymmetric structure installed at the substation. Reactive currents of the compensating device allow to redistribute between phases of the traction transformer active and reactive power of asymmetric traction load and to receive symmetric load of three-phase power supply system. The theorem is proposed to determine the conductivities and reactive currents of the branches of a compensating device with an asymmetric structure depending on the traction loads. The article presents the calculated expressions, which can be used to calculate the conductivity and reactive currents of the branches of the compensating device for any traction load of the feeders, in which the equivalent load, including the reactive currents of the branches of the device and the currents of the feeder zones will be symmetrical and active. As an example of the application of the theorem and the proposed expressions, a test problem is presented in which the secondary winding of a traction transformer with asymmetric traction load of feeders is considered, the conductivity of the branches of the device is calculated. With the use of vector diagrams shows the receipt of a symmetrical system of currents of the secondary winding of the traction transformer. Mathematical expressions allowing to realize the necessary law of regulation of reactive currents of the device are given. The necessary ranges control of reactive currents of the compensating device on traction substation on the set probabilistic laws of change of traction loadings are defined. Various options for the practical implementation of a compensating device that will provide the necessary inductive or capacitive current of each branch are considered.
  • V.4(28), 2016
    101-108

    Determination of parameters of compensating devices with asymmetric structure for reduction of voltage unbalance and reactive power compensation in the low-voltage three-phase electrical network

    The article considers one of the ways of improving the energy efficiency of three-phase power supply system of industrial and railway enterprises. Presented and proved a theorem, which allows to determine the necessary conductivity and the reactive branch currents compensating device with asymmetric structure, for which the equivalent conductivity of these elements and the load will be symmetrical and active. In three-phase electric circuit of an alternating sinusoidal current reactive elements allow to redistribute active and reactive power between the phases. The use of a compensating device with asymmetric structure will reduce losses from the occurrence of reactive currents, reverse currents and zero sequence in low-voltage three-phase power system. As an example of the use of the theorem and the calculated expressions for determination of conductance of the branches of the asymmetric compensating devices a special test problem was considered. It shows the values of power losses, the coefficients of voltage unbalance with and without using the device. Considered possible options for the practical implementation of such technical devices.
  • V.2(42), 2020
    103-114

    Development of an algorithm and method for calculating the open-operated electric network with a voltage of 6-35 kv taking into account the temperature dependence of active resistance

    This article presents an algorithm and a method for calculating power flow of an open electric network with a voltage of 6-35 kV, taking into account the temperature dependence of active resistances. Calculation of the electric and thermal conditions of the electric network is carried out with a joint solution of the equations. The determination of stresses in the nodes is carried out using the inverse matrix of the nodal and intrinsic conductivities. The inverse matrix of nodal and intrinsic conductivities is determined based on the well-known direct Jordan-Gauss method. The equation of the heat balance of the wire used to calculate the actual temperature is solved numerically. Convective heat transfer is recorded only for forced convection, because wires of overhead power lines with a voltage of 6 kV and higher are located on various types of poles, at a height of at least 10 m. This fact allows us to abandon the use of formulas for natural convection and use expressions only for forced convection. Accounting for solar radiation in the presented algorithm is possible on the basis of two methods: simplified and considered in the standard of PJSC FGC UES, which allows you to take into account the actual location of the wire relative to the north. Using the test circuit as an example, the steady-state mode was calculated taking into account the temperature dependence of the active resistances. The results of a numerical experiment are presented, confirming the operability of the developed algorithm. The refinement in determining active power losses with and without taking into account the heating factor for the considered circuit is about 13%. Verification of the algorithm that implements the method of calculating the steady state (SS) of an open electrical network of a medium voltage class taking into account the temperature dependence of active resistances showed that in technically acceptable modes the developed algorithm has good accuracy in comparison with the RastrWin3 software package.
  • V.2(34), 2018
    106-112

    Evaluation of energy efficiency of train motion schedules based on modeling by nonlinear regression and neural network methods

    The article deals with the modeling of the electric rolling stock and traction power supply system with the aim of solving the problem of reducing the electric power consumption for the traction of trains in the conditions of changing the schedule of freight trains. Simulation modeling is performed for the conditions of changing the mass of the train and the load on the axis. The description of the results obtained is based on regression models, the order of application of models in practice is given.
  • V.4(28), 2016
    115-124

    Efficiency evaluation of use of regime automatic equipment of reserve converting aggregates on the basis of the analysis of load graphs in case of the existing settings

    In article the algorithm of operation of the existing regime automatic equipment of transforming aggregates is considered. Earlier it was read that use of automatic equipment of switching on switch-off of reserve transforming aggregates is an effective remedy of lowering of losses in case of regulation of power of substation depending on tractive loading. Defining factors of assessment of efficiency of automatic equipment are the current and temporal settings, and also restriction of number of switchings in days. The analysis of diagrams of tractive loading showed that there is rather large number of temporal intervals where operation of automatic equipment is ineffective. On the one hand it is connected to the fact that loading is above a point of equality of losses in case of one and two transforming aggregates quite short time, and automatic equipment connects the reserve transforming aggregate already in the course of lowering of loading and disconnects it after a temporal setting. On the other hand - operating restriction of number of switchings of the reserve transforming aggregate in days doesn't allow to gain the considerable economic effect. The decision on use of regime automatic equipment with the existing settings can be the positive if at the same time the estimated effect in the form of abbreviation of losses of the electric power is above cumulative damage from switching of the reserve transforming aggregate. Regime automatic equipment in most cases, it is necessary to consider not as means of obtaining economic effect, and as means of reliability augmentation of operation of semiconductor rectifiers at the peak moments of loading what in turn influences reliability of electrical power supply of pull of trains in general.
  • V.3(39), 2019
    134-145

    Assessment of solar radiation effect on real-power losses under load in high-temperature and self-supporting insulated wires of power lines

    The use of new self-supporting insulated wires and high-temperature wires in the operation of power lines allows increasing the capacity of lines and, as a rule, reducing operational costs. An optimal utilization of the power line load capacity depends on the precise determination of the permissible current loads. The values of permissible currents and steady-state temperature are the main parameters of the line operating mode, affecting the strength and sag of the conductor. The temperature of the wire depends on weather conditions and current load. There are methods for determining the temperature and permissible currents for widely used traditional wires such as AC. They are partially outlined in the EIS (Electrical Installation Standard) and the standard of PJSC FGC UES (Federal Grid Company of Unified Energy System) of 2013. However, there is lack of studies in new types of wires. The paper considers the effect of weather conditions and load on the temperature and real-power losses in insulated and high-temperature wire, and solar radiation is under special consideration. For comparison, we present the results of calculations on traditional AC wires. The research shows that solar radiation, being taken into account, provides an increase of real-power losses of about 2 % with the given values of load and weather conditions. Calculations of permissible current values according to the developed technique for classical AC wires reveal a high coincidence with the values from PJSC FGC UES standard. The relative error is within two percent, and the proposed method is more generalized. It allows simultaneous analysis of both uninsulated and insulated wires. Due to the widespread use of self-supporting insulated wires, power industry experts can use the developed software in the design and operation of modern power lines to optimize capacity.