• Рус Русский
  • Eng English (UK)

Scientific and technical journal established by OSTU. Media registration number: ПИ № ФС77-75780 dated May 23, 2019. ISSN: 2220-4245. Subscription index in the online catalog «Subscription Press» (www.akc.ru): E28002. Subscription to the electronic version is available on the «Rucont» platform.
The journal is included in the Russian Science Citation Index and in the List of Russian Scientific Journals .

Search results

  • V.1(41), 2020
    50-58

    Methods for selecting settings reserve power system of dc traction substations

    The article discusses methods in evaluating the current settings for turning on and off the second converter unit when introducing power backup systems for DC traction substations. The analysis of the advantages and disadvantages of existing methods. The algorithm for calculating the current settings. A comparative analysis of the operating currents of the automation of the converter unit is carried out on the example of traction substations of the current section of the West Siberian Railway.
  • V.2(14), 2013
    51-58

    Increasing efficiency of traction network dc railway using energy storage devices

    There is a trouble that electrical energy of trains which have a recuperative braking uses partly for DC railway, because there are not different consumers of the electrical energy in this time. The method was offered, it allows to find optimal parameters of a stationary energy storage, which locates on a traction substation. This method can be used for designing and determination efficiency of an energy storage.
  • V.4(16), 2013
    51-58

    An energy storage device parameters determinationfor electrical locomotives of dc railway

    There is the way for increasing efficiency of recuperative braking, using an energy storage device on electrical locomotives of DC railway. This device must store a part of recuperative energy. In the article the approach was considered, which allows to find parameters of an energy storage device, this device must be placed on electrical locomotives of DC railway, a part of recuperative energy can be returned to electrical network.
  • V.3(39), 2019
    57-67

    Assessment of the moscow central ring energy efficiency potential through the use of rectifier-inverter converters

    This article presents the results of changes calculations in the energy efficiency indicators of the Moscow Central Ring, such as the specific consumption of electricity released for traction by trains of traction substation meters, specific recovery, technical losses of electricity in the traction power supply system when it is transferred to electric rolling stock, including technical recuperation energy loss, depending on various installation options of rectifier-inverter converters in traction substations part.
  • V.1(21), 2015
    59-69

    Optimization of graphic time-table to the criterion of electrical energy’s expenditure for traction on the railways sections in the conditions of using the regenerative braking

    A method to an assessment of influence on the expenditure of electrical energy for traction of trains, parameters of graphic time-table in the conditions of using the regenerative braking is being considered in the article. The retrieval of version with the minimal using of energy is based on the modeling of graphic time-table by different train-to-train intervals in the conditions of burst-mode access’ organization on the railway section. By results of modeling it is proposed to represent the derived dependence by changing of electrical energy’s expenditure on parameters of graphic time-table in the form of analytic function of several variables n-order forthe following using by normative plotting of movement for the purpose of curtailing electrical energy’s expenditure for traction on the trains.
  • V.4(36), 2018
    60-68

    Analysis and assessment of power efficiency of special self-propelled railway rolling stock

    Electric power installation of a special self-propelled rolling stock used in the power supply divisions is considered in the paper; the expediency of its use for the analysis of the main energy indices, in particular, the evaluation of the efficiency of electro-hydro-mechanical units at separate and joint operation, is shown. To assess the energy efficiency, an integrated efficiency factor has been proposed that allows to account the energy parameters of electrical installations operating in various modes. Recommendations have been given to increase the power factor of electrical installations.
  • V.1(25), 2016
    60-70

    Methodology for assessing the energy efficiency of regenerative braking the use and energy recovery

    The article analyzes the components of the energy efficiency of regenerative braking and the factors influencing the effectiveness of the use of regenerative braking and energy recovery. Methods of evaluating the energy efficiency of recovery and the results of experimental studies of the effectiveness of recovery. Achieved justification for the use of the method of simulation modeling as a method for evaluating the potential of regenerative braking. It shows the sequence of the work.
  • V.3(23), 2015
    62-68

    Evaluation of power losses in nodes underframes of locomotives

    The article proposes methodology for assessing the power loss in motor thrust bearings, the nodes of box, traction gear transmission. Revealed dependence between the power losses, the diameter of the tire wheel pair and the speed characteristic of the wheel-motor block. The results can be used to assess the technical condition and energy efficiency of traction rolling stock of Railways.
  • V.2(34), 2018
    65-75

    Study of operation modes of the electrical power supply system for installation of electric energy storage drivers

    The article deals with issues related to theoretical and experimental studies of operating modes of the traction power supply system. The analysis of the comparison of voltages on the tires of traction substations with uncontrolled rectifiers and tires of traction substations with converter units equipped with a system of non-contact automatic voltage regulation is shown, the differences between them are shown. The modes of operation of the active partitioning post with the point of increasing voltage have been studied in detail. As a result of research, it was found that the observation time of maximum voltage values at substation tires above the average no-load voltage level is about 5 -10% of the time of day, about 7 - 8% at active posts, and 10 - 13% at passive posts. The maximum power in the active mode of the post sectioning with the point of increasing the voltage at lower voltage in the contact network is 2.9 MW. The average amount of electricity returned to the contact network point of increase of voltage, in one case is 170 kWh. The average duration of work in active mode for one case is 8,6 minutes.
  • V.4(44), 2020
    65-75

    Principles of classification of influencing factors on the energy consumption of electric rolling stock

    The known approaches to the classification of factors affecting the energy consumption of the train are considered, and their main disadvantages are identified. The validity of existing classification methods and the completeness of accounting for factors affecting energy consumption are evaluated. It is shown that none of the known approaches to classification gives a complete picture of all the influencing factors and the degree of their influence on the energy consumption of the train, since it does not fully take into account the physical nature of the individual components and the overall power consumption for traction. Based on the analysis of the energy balance of the train articulated principles and criteria for the classification of factors influencing energy consumption, considers the interconversion of different forms of energy and describe their energy diagrams in the different modes of the train movement. The analysis made it possible to identify the factors that affect the power consumption of the train in all modes of movement, and evaluate them according to various criteria. A classification of factors affecting the train's electricity consumption is proposed, which allows us to justify the correct method of accounting for each factor, develop measures to reduce the influence of individual factors on energy consumption, improve the system of analysis, rationing and forecasting of electricity consumption for train traction, and competently solve other problems of electric traction energy.
  • V.4(52), 2022
    66-75

    To the study of the efficiency of locomotives of electric traction in the kokand - andijan section of the uzbek railway

    The subject of research is the evaluation of the effectiveness of different modes of energy-optimal control of the movement of a freight train of a unified mass by AC freight electric locomotives of the Uz-El series with asynchronous electric motors on the flat section of Kokand - Andijan of the Uzbek railway. Purpose of the study: substantiation of the main performance indicators of electric traction locomotives, taking into account the given traffic schedule, using various options for the optimal mode of controlling the movement of a freight train with a unified train mass on a real flat section of the Uzbek railway. The methods and methodology of the research are the theoretical foundations of locomotive traction, the mathematical theory of optimal object control, as well as the C # programming language (C Sharp) with the development of mock-up applications in the Microsoft Visual Studio 12.0 programming environment.As a result of the study, energy-optimal curves, kinematic parameters of the movement of a freight train and parameters of the main indicators of the energy efficiency of the investigated electric locomotive for different options for traction calculation on the real flat section of Kokand - Andijan of the Uzbek railway were obtained. The obtained kinematic parameters of the movement of freight trains with a unified mass of the train and the parameters of the efficiency indicators for the use of the studied electric locomotives can be used in the Kokand locomotive depot, which will allow developing regime maps for driving freight trains by these electric locomotives, depending on the level of complexity of the track profile and various conditions for organizing rail transportation of goods.
  • V.3(43), 2020
    66-75

    Monitoring of performance indicators of electric rolling stock and power supply devices using big data processing technologies

    The article presents the main results of experimental studies within the boundaries of the Fadino - Novoseletsk, Novoseletsk - Strela interstitial zones of the Entrance - Irtysh section. As a result of the research identified problems that currently hinder the online monitoring of operational parameters of the electric rolling stock (EPS) and power supply devices: a lack of data on the work of the traction substations, the presence of EPS without registration motion parameters (RAPS), the lack of process data collection with RAP, the lack of a single source and process for obtaining data, insufficient memory storage device of cartridge, lack of data latch on the locomotive in General, lack a set of fixed parameters, non-constant sampling of parameter fixing, insufficiently detailed final documentation, imperfect software for exporting data from cartridges and lack of binding to global time. Shown the possibility of joining data from different automated systems of JSC "RZD" and measuring systems OSTU, which will allow us to estimate the losses in the traction network, the expense on own needs of electric rolling stock , the electric power consumption for traction and return of electric energy to contact network, as well as move forward with implementation of predictive control operation modes of the electric rolling stock and power infrastructure and Railways in a changing environment in the transportation process, to ensure the best conditions for the realization of tractive effort, regenerative braking, set train schedules, including in case of critical restrictions on the part of the power supply system, preventing train traffic from stopping.
  • V.4(24), 2015
    68-75

    Standard legal support activities for energy saving in holding «russian railways»

    Results of the analysis of normative and legal documents of the Russian Federation, and also the internal normative documents establishing the main target indicators and requirements to activities for energy saving in «Russian Railways» Holding are given in article. Need of carrying out updating of Power strategy of «Russian Railways» Holding and revision of the list is proved by the mechanism of its realization.
  • V.3(23), 2015
    68-72

    The utilization of secondary energy resources during the conduct of rheostat trials

    Rheostat trials must be carried out after repairing of a diesel locomotive. As a rheostat it is used a complex of equipment and it is taken a separate building for the staff, which must be situated at a set distance from office buildings. In order to keep the building for the staff warm central heating is used. The net cost is extremely high and transit heat losses are often comparable with effective consumption of the heated building. In this work the possibility to utilize the secondary energy resources for heating the stations is considered where rheostat trials are supposed to be carried out. It is noticed in separate depots that the measures of heat energy utilization from load rheostats have already been applied, but they are not widespread. There are external restrictive factors which limit the adoption of heat-recovery installations and also technical and organizational factors as well. There have been proposed principal measures which could be considered in case of the adoption of heat-recovery installations. Calculations are performed by heat energy generation by a rheostat during typical trials of diesel locomotives TEM2 and heat quantity of heat-transfer agent in typical load water rheostats. It is proposed that the plan to utilize secondary energy resources in low temperature heating systems will be effective. It is also mentioned the utilization of low temperature heating systems has many advantages. The required heat energy generation of heat-recovery installation for each month of the year have been calculated, and Station Omsk depot is one of the example where these calculations have been performed. It is noted required quantity of trials for heat loss compensation coincide with station operating schedule of rheostat trials in the majority of depots and would like to apply the indicated trial method. The calculated economical cost of these measures along with capital costs for the speed of completing the building should be considered when calculating the total cost of the station over the open rheostat tank.
  • V.4(40), 2019
    70-77

    Utilization of secondary energy resources load testing of locomotives

    The article deals with the possibility of energy utilization of exhaust gases of diesel-generator sets of locomotives during load tests. The calculation of the amount of heat carried out during tests with exhaust gases. Possible variants of heat utilization with the use of various heat exchangers are considered.
  • V.1(37), 2019
    72-81

    Using the liquid oil-containing waste products of railway depots for heat energy generation

    The used liquid wash solutions utilization problem in railway depots of Russian Federation was overviewed. Postulated, that it is important to solve ecological and energy efficiency problem together on railways. Authors shows, that in this moment level of development and using resource saving technology in railway depots is too low. Economical, juridical and technological aspect of this problem was analyzed. Shows, that in present conditions we need to treat wash solutions in the closed water recycling process. Simultaneously waste products must be concentrated and then used, taking into consideration, that concentrated waste products contains flammable oil-products. Proposed to combust it and generate heat energy. Taking review of oil-containing waste products concentration and combustion methods. Shows, that heat energy can be used for grows up energy efficiency of railway depots. Described theoretical basics, results of carried experiments, and economic effect was estimated. It`s proved, that proposed technology is useful and can be realized. Preferred construction of washing machines and waste treatment facilities are recommended. Ways of next research work are selected and proved.
  • V.1(29), 2017
    74-83

    Influence of parameters and operating modes traction power supply system on efficiency of energy recovery use

    The article analyzes the influence of parameters and operating modes of traction power supply system on the value of the useful energy recovery and the amount of electricity losses caused by the energy recovery through the traction power system to various consumers. The amount of energy lost in recuperation determines the degree of efficiency of its use. The approaches to the sequential determination of the recuperation energy efficiency and the calculation of the numerical values of the quantities characterizing the parameters of the traction power supply system, which are necessary for an adequate analysis of the energy distribution flow distribution, are proposed. It is determined that it is sufficient to use the regression analysis method to estimate the influence of the parameters and operating conditions of the traction power system on the energy efficiency of the recovery. The values of the relative resistance of the contact network are calculated depending on the type of the contact suspension, as well as on the traction network supply circuits. It is shown that the parameters and operating modes of traction power supply system affect the losses in the contact network, the losses in rectifier-inverter converters and traction transformers of direct current traction substations, the amount of energy recovery from tires of traction substations, as well as the relative change in losses in the system traction power supply with the use of regenerative braking.
  • V.2(38), 2019
    75-82

    Improving the methodology of control the locomotives use efficiency to the train traction

    With the advent of new series of locomotives, the development of heavy freight trains, the increasing speeds of passenger trains, the introduction of innovative technical means and technologies, the degree of influence of various indicators on energy consumption is redistributed. The aim of the article is to develop a methodology for monitoring the efficiency of locomotives when changing the set of operational factors. This will make it possible to more accurately determine the estimated change in specific energy consumption, which in turn will increase the objectivity of the assessment of the causes of changes in the energy intensity of transport and will help to reduce energy losses.
  • V.3(19), 2014
    75-81

    Determination of the optimal parameters of energy storage devices to manage railway's electrical loads

    The article describes a method for controlling electrical loads rail consumers using energy storage. Different types of energy storage devices used in rail transport were considered. Performed the optimization problem formulation, selected criteria and the method for its solution. As an optimization method used the method of Hooke-Jeeves. A method is proposed to determine the optimal parameters and the optimal control law of charging and discharging of the energy storage. The criteria and calculation expressions that can be used in the design and feasibility study of the effectiveness of implementation of the stationary energy storage for managing schedules loads rail consumers. The mathematical expression was proposed for the energy storage capacity determination. Two criteria were considered in the optimization problem: a minimum active power losses and minimum reduced costs, and a comparison of results. The form factor used to evaluate the changes in electrical loads. Control of reactive power in the AC mains can realize using semiconductor converters and an energy storage. As a variant the electrochemical cells (lithium-titanate batteries) could be used as energy storage for rail electric consumers. As a result, optimal control of electrical loads allows to get technical and economic effects.
  • V.2(14), 2013
    75-84

    Evaluating the potential of energy efficiency of the system of traction electric supply

    The article sets forth the procedure for preparation of energy saving programmes for the system of traction electric supply. List of key measures aimed at reduction of losses of electric power in traction network and equipment of traction substations, and also on increase of carrying capacity of railway sections. Presents the results of studies evaluating the potential of energy efficiency of the system of traction electric supply of Railways.
  • V.2(34), 2018
    76-85

    The development and approbation technologies of increasing energy efficiency of production processes in service locomotive depo

    The article analyzes the results of the assessment operating time and power consumption of compressor equipment service locomotive depo Moscow West-Siberian Railway. The algorithms for data preparation for modeling and evaluating the efficiency of the production process are presented. The main factors influencing the power consumption of the compressor equipment are determined and the results of the assessment of their influence are presented. On the basis of the dependences obtained, a mathematical model of the process of power consumption of compressor equipment using fuzzy neural networks and its accuracy is determined. The interface of the developed program complex is presented at an estimation of influence of factors on process of power consumption of the equipment service locomotive depo Moscow West-Siberian Railway.
  • V.4(40), 2019
    77-86

    Increasing the efficiency of warming of building walls taking into account the regulation of the released heat energy

    Optimization of insulation of walling of building walls is proposed, taking into account the relationship of structural, heat engineering, operating parameters and economic indicators. The purpose of research is to determine the optimal value of the thickness of the insulation with the heat-insulating material of the object, taking into account the thermal energy released to it. The study used methods of mathematical modeling of heat transfer, an optimization problem. The results of the study of the influence of the thickness of the insulating material on the technical and economic efficiency of the building's consumption of energy resources and material costs are presented. The results showed a decrease in heat losses through the building envelope, consumption of heat and electric energy for the heating, ventilation system and reduced costs.
  • V.4(20), 2014
    79-85

    Approbation of algorithm evaluating the effectiveness of energy-saving devices and technologies in the traction power supply system

    This paper describes an algorithm evaluating the effectiveness of energy-saving devices and technologies, based on the methods of mathematical statistics. Diagram presented in the article. It can be applied in the traction system and power supply without traction. Approbation of the algorithm is executed in the traction power supply system. The developed algorithm includes five stages: 1. Stage calculate the required number of observations. The basis of this stage is to evaluate the dispersion and calculating on it the desired number of observations. 2. Stage of the collection and processing of data obtained before the implementation of energy-saving devices and technologies. Collection is carried out on of electricity consumption and factors influencing the process of electricity consumption. Processing includes the calculation of the correlation matrix, the coefficients of determination and the parameters of the regression equation. 3. Stage of the collection and processing of data obtained after the implementation of energy-saving devices and technologies. Data collection is carried out according to the parameters selected in step 2 and the processing is done by the calculation of the parameters of the regression equation. 4. Stage of comparing the data before and after the introduction of energy saving devices and technologies. Comparison of the data obtained before and after the introduction of energy saving devices and technologies produced using the Chow test and nonparametric mathematical statistics such as omega-square (Lehmann-Rosenblatt). 5. Stage of calculating electric power saving. The calculation is made on the consumption of electricity obtained by the regression equation before the introduction of energy-saving devices or technology by substituting the values of the factor after implementation and actual consumption of electricity after the introduction of energy-saving devices or technology. Approbation of the algorithm was successful.
  • V.1(33), 2018
    79-87

    Electrical distribution networks of railway junctions. problems and solutions

    The article describes the current state of railway non-traction electric power supply system in the electric grid complex. The main drawbacks of the existing electricity metering system in 0.4-10 kV distribution networks are shown. The main directions of non-tractive electric grid complex innovative development are considered, including directed to increase the efficiency of electric energy transformation, transmission and consumption processes due to the management of distribution networks operating modes. The basic principles of "Digital district power supply" constructing are given.
  • V.1(29), 2017
    83-90

    Organization of control limit operation mode traction network in the speed and heavy movement

    The paper discusses the use of automated electricity metering systems to control parameters of the traction power supply system in terms of speed and heavy movements. As the main control system offered an automated system for monitoring energy efficiency of transportation process. The results of testing of the system considered in the measurement example, the boundaries of the active area of railways DC Shalya - Podvoloshnaya Sverdlovsk railway.